Service-oriented drives work to reduce energy usage.
Schneider Electric

Regulatory agencies are releasing new standards that bolster pump and pump system energy efficiency standards and boost global sustainability efforts. In the U.S., for example, the Department of Energy estimates that the National Electrical Manufacturers Association (NEMA) premium-efficiency motor program will save 5.8 terawatts of electricity and prevent the release of nearly 80 million metric tons of carbon into the atmosphere over the next 10 years. This is equivalent to keeping 16 million cars off the road.

In Europe, the Committee for Electrotechnical Standardization (CENELEC) has released the EN50598 standard, which assesses power drive systems and makes recommendations for designing more environmentally friendly power applications. The standard was also adopted by the International Electrotechnical Commission (IEC) under international standard IEC 61800-9-2:2017. This focuses on system-wide efficiency on top of traditional individual component efficiency. The subsystems targeted by EN50598-2 include complete drive modules, or CDMs (made up of a frequency inverter, a feeding section, a basic drive module and auxiliaries), and power drive systems, or PDSs, (made up of the complete drive module plus a motor). Per the standard, “auxiliaries” refer to devices such as output filters and line chokes.

International efficiency (IE) classifications for the CDMs are defined by comparing the total power loss of the CDM at 90 percent of the output voltage to 100 percent of the torque-generating current of what is identified by the group
as a “reference CDM.”

Maximizing pump efficiency is a greater focus than ever.Image 1. Maximizing pump efficiency is a greater focus than ever. (Images courtesy of Schneider Electric)

The PDSs have their own classifications referred to as IES (the collation of IE levels of motors and CDMs). As with CDMs, a reference PDS (RPDS) is introduced by the standard. The RPDS allows the comparison of the energy consumption of an average technology PDS at eight predefined operating points. IES classes are determined by comparing the power losses of the PDS in question with the RPDS values.

Other directives such as the European Commission’s Ecodesign recommendations have been, as of January 2017, altering minimum efficiency requirements for motors. Motors with rated outputs of 1 to 500 horsepower (hp) must meet IE3 (premium efficiency) levels or must be equipped with a variable speed drive (VSD) if they are at IE2 (high efficiency) levels. Pump manufacturers have begun to equip their systems with these higher efficiency motors, and they expect service-oriented drive (SOD) manufacturers to help enable simpler operation of asynchronous, permanent-magnet and synchronous-reluctance motors.

Practical Implementation of High Efficiency

Pumps and motors connected to drives are primary targets for efficiency improvements. In fact, energy costs represent 40 percent of the total cost of ownership (TCO) of a typical pump. Technologies such as VSDs and SODs offer significant potential for reducing the energy consumption of pump and motor systems.

When connected to motors and pumps, VSDs can be more efficient than traditional fixed-speed driven equipment.

Regulatory bodies are now examining system-wide efficiency for new standardsImage 2. Regulatory bodies are now examining system-wide efficiency for new standards.

VSDs adjust to the application need, thereby slowing down or speeding up when predefined and dynamic conditions trigger the required changes and reducing or optimizing energy consumption.

The latest VSD iteration, the SOD, comes with added intelligence, which allows embedded energy and asset management services capabilities. SODs can measure energy consumption of driven equipment (motors and pumps) and monitor performance of those assets. They can also improve energy performance through adjustment of operational parameters and record the data for analysis. With respect to pumps, the SODs measure the power consumption and pump characteristic curves (such as head-flow), which allows tracking of operating pump efficiency in relation to the pump’s best efficiency point (BEP).

Comparison of energy consumption at eight predefined operating pointsImage 3. Comparison of energy consumption at eight predefined operating points

SODs also bring configuration ease to the user and let them control multiple-pump systems efficiently to avoid extra energy consumption, vibrations and unnecessary pressure buildups.

An SOD can run the optimal number of pumps at the necessary speed to meet the demand of the pumping system and maintain the lowest possible power consumption (working closest to the system BEP) by minimizing specific energy consumption key performance indicators (KPIs). This KPI is basically the energy consumed per water pumped.

VSDs offer significant potential for reducing pumping system energy consumption.Image 4. VSDs offer significant potential for reducing pumping system energy consumption.

As SODs have advanced user interfaces, equipment performance can be monitored via a local control panel or even remotely via a mobile device. This helps simplify the maintenance process. The SODs perform advanced asset diagnostics, which helps to drive optimized predictive maintenance strategies. Asset performance of the drive, motor and pumps are all monitored.

The possibility of performing true predictive maintenance helps replace what needs replacing without incurring unanticipated downtime, saving hundreds of hours and tens of thousands of dollars per year.

VSDs with added intelligence can provide process data directlyImage 5. VSDs with added intelligence can provide process data directly.

Read more Maintenance Minders articles by clicking here.